Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-064-6796 Item Description: Switch Thermostatic | 5930 | 000646796 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
025-09515 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | III OVERALL LENGTH | 5.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 5.406 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.688 INCHES NOMINAL |
ADAQ | BODY LENGTH | 4.782 INCHES NOMINAL |
AEVT | CAPILLARY TUBE LENGTH | 720.000 INCHES NOMINAL |
AEVU | BULB LENGTH | 6.000 INCHES NOMINAL |
AEVV | BULB DIAMETER | 1.125 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
AXGY | MOUNTING METHOD | BRACKET |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CSCF | TERMINAL TYPE | TAB W/SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 3.4 AMPERES RESISTIVE LOAD SINGLE VOLTAGE AND 2.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | -10.00/+50.00 ACTUATION POINT DEGREES FAHRENHEIT |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL SECOND VOLTAGE |
FEAT | SPECIAL FEATURES | OMOUNTING DIMENSIONS,THREE 0.281 IN. DIAMETER MOUNTING HOLES,TWOHOLES ON TOP SPACED 2.406 IN. C TO C,ONE HOLE ON BOTTOM 0.547 IN. TOTHE LEFT OF VERTICAL CENTERLINE,3.281 IN. VERTICAL DISTANCE BETWEENMOUNTING CENTERS |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE VOLTAGE |
025-0008 | 025-00093 | 025-0001-668 | 025-0008-00 |
025-000221E | 025-0005 | 025-0001-668 | 025-00088 |
025-000153 | 025-0000-012 SIZE 40 | 025-0006-01 | 025-0008-00 |
025-0002-00 | 025-0006-01 | 025-00056 | 025-0005 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote