Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-00-923-1328 Item Description: Capacitor Variable | 5910 | 009231328 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
8773931-3 | 2 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | PISTON |
ABHP | OVERALL LENGTH | 0.638 INCHES MINIMUM AND 0.700 INCHES MAXIMUM |
ABJT | TERMINAL LENGTH | 0.969 INCHES MINIMUM AND 1.031 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.519 INCHES MINIMUM AND 0.559 INCHES MAXIMUM |
ADAV | OVERALL DIAMETER | 0.297 INCHES MINIMUM AND 0.329 INCHES MAXIMUM |
AEBF | TEMP COEFFICIENT OF CAPACITANCE RANGE IN PPM PER DEG CELSIUS | -50.0/+50.0 SINGLE SECTION |
AEBS | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER | 0.229 INCHES MINIMUM AND 0.239 INCHES MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.032 INCHES NOMINAL |
AECJ | QUALITY FACTOR AT 25 DEG CELSIUS | 500.0 |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
AXGR | ADJUSTMENT DEVICE TORQUE | 1.000 INCH-OUNCES MINIMUM AND 10.000 INCH-OUNCES MAXIMUM |
AXGT | INSULATION DC RESISTANCE AT 25 DEG CELSIUS | 1000000.0 MEGOHMS |
AXGX | INSULATION DC RESISTANCE AT MAX OPERATING TEMP | 100000.0 MEGOHMS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 TERMINAL |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
CTGN | CAPACITANCE RANGE IN PICOFARADS | +1.5/+16.0 SINGLE SECTION |
CTGP | NONDERATED VOLTAGE RATING AND TYPE | 1000.0 DC CONTINUOUS SINGLE SECTION |
CTGR | ADJUSTMENT DEVICE DRIVE TYPE AND QUANTITY | 1 SLOTTED SCREW |
CTGS | CAPACITANCE DRIFT IN PICOFARADS | 0.02 SINGLE SECTION |
MATT | MATERIAL | GLASS CAPACITIVE ELECTRODE |
MATT | MATERIAL | METAL BASE |
TTQY | TERMINAL TYPE AND QUANTITY | 1 SOLDER STUD AND 2 WIRE LEAD |
877-041 | 877-00092-000 | 877-009-012 | 877-009703Y00 |
877-009-020 | 877-009703X-00 | 877-001C | 877-009-018 |
877-008928Y00 | 877-009703Y-00 | 877-009-017 | 877-008366X-00 |
877-009-002 | 877-009-021 | 877-008928Y00 | 877-014C |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |