Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-00-481-4540 Item Description: Capacitor Fixed Gla | 5910 | 004814540 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
108-818-0037 | 2 | 2 | 1 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.125 INCHES MINIMUM |
ADAQ | BODY LENGTH | 0.390 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.200 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.109 INCHES MAXIMUM |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.285 INCHES MINIMUM AND 0.315 INCHES MAXIMUM |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
CQBQ | CAPACITANCE VALUE PER SECTION | 10.000 PICOFARADS SINGLE SECTION |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
CQLZ | III TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS | 0.0 SINGLE SECTION |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 500.0 DC SINGLE SECTION |
CRHD | TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS | -25.0 TO 25.0 SINGLE SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -5.00 TO 5.00 PERCENT SINGLE SECTION |
CWJK | CASE MATERIAL | GLASS |
CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 10000.0 MEGOHMS |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.0030 |
CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
TEST | TEST DATA DOCUMENT | 95542-108-818 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
108-000-026 | 108-000-025 | 108-000-031 | 108-000-025 |
108-000-034 | 108-000-036 | 108-000-034 | 108-000-034 |
108-000-052 | 108-000-031 | 108 000 060 | 108 000 038 |
108-000-046 | 108-000-060 | 108-000-034 | 108 000 036 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote