Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-01-152-0055 Item Description: Resistor Network Fi | 5905 | 011520055 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | A | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
SM A 838229 17 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -100.0/+100.0 |
AAPP | ELECTRICAL RESISTANCE | 12.100 KILOHMS |
AAPP | ELECTRICAL RESISTANCE | 3.160 KILOHMS |
AAPP | ELECTRICAL RESISTANCE | 3.430 KILOHMS |
AAPP | ELECTRICAL RESISTANCE | 56.200 KILOHMS |
AAPP | ELECTRICAL RESISTANCE | 6.980 KILOHMS |
AAPP | ELECTRICAL RESISTANCE | 9.090 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -2.000/+2.000 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 70.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 150.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0/+150.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARA | TERMINAL QUANTITY | 8 |
AARB | TERMINAL TYPE | PIN |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.150 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.800 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.125 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.350 INCHES MAXIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 1.250 TOTAL NETWORK |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 1ST INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 2ND INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 4TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 HIGHEST RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 LOWEST RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 2 3RD INTERMEDIATE RESISTANCE VALUE |
STYL | STYLE DESIGNATOR | SINGLE INLINE |
TEST | TEST DATA DOCUMENT | 80063-SM-A-838229 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING |
SM-024 | SM-011 | SM-0015GMV | SM-0545020 |
SM-05 | SM-036-0030-AB | SM-009 | SM 024 0045 HL |
SM-02-Z | SM-024-0045-HL | SM-012 | SM-002 |
SM-0640M | SM-0015GMV | SM-0015GMV | SM-036-0030-AB |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote