Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-305-5348 Item Description: Power Supply Assemb | 6130 | 013055348 | N | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | 0 | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
23211 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 5.312 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 19.000 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | FUNGUS PROOF |
AEAS | MAJOR COMPONENTS | RACK ADAPTER NSN 6130-01-162-5959MODEL LRA-15; POWER SUPPLY NSN 6130-01-084-3246 MODEL LNS-Y-5-OV; POWER SUPPLY MODEL LNS-X-28-42769; (2) POWER SUPPLIES 6130-01-138-1685 MODEL LNS-Y-15;(2) OVERVOLTAGE PROTECTOR 5962-01-087-2308 MODEL L-6-OV |
AGAV | END ITEM IDENTIFICATION | AN/FPS-117(V) |
AJJY | DOCUMENT SOURCE | 80103 |
AJKA | DOCUMENT IDENTIFICATION | 23211 |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 210.0 AC POUNDS PER HOUR DRY 1ST ALTERNATE OPERATING POWER RQMT AND 254.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 1ST ALTERNATE OPERATING POWER RQMT |
APPA | III OUTPUT VOLTAGE RATING | 14.2 DC VOLTS MINIMUM AND 15.7 DC VOLTS MAXIMUM 3RD POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
AQHK | COMPONENT CONTROLLING AGENCY | LAMBDA ELECT |
AYNH | OPERATING AMBIENT TEMP RANGE | -0.0/+71.0 DEG CELSIUS |
BGQF | POWER UNIT QUANTITY | 4 |
CBBL | FEATURES PROVIDED | ON-OFF SWITCH-INDICATOR AND DIGITAL AMMETER AND DIGITAL VOLTMETER AND REMOTE ERROR SENSING CAPABILITY AND VOLTAGE ADJUSTMENT AND OVER VOLTAGE PROTECTOR AND OVER CURRENT PROTECTOR AND FUSE AND INPUT TO OUTPUT ISOLATION AND INPUT TO CASE ISOL |
CWGH | OUTPUT CURRENT RATING | 2.0 DC AMPERES MINIMUM 2ND POWER OUTPUT AND 3.4 DC AMPERES MAXIMUM 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 2.4 DC AMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 3.1 DC AMPERES MINIMUM 4TH POWER OUTPUT AND 6.0 DC AMPERES MAXIMUM 4TH POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 8 SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP SINGLE POWER OUTPUT |
FEAT | SPECIAL FEATURES | OUTPUT TERM COVERS |
AQHM | COMPONENT IDENTIFYING NUMBER | 23211 DRAWING NO. |
CWGH | OUTPUT CURRENT RATING | 2.0 DC AMPERES MINIMUM 3RD POWER OUTPUT AND 3.4 DC AMPERES MAXIMUM 3RD POWER OUTPUT |
ABHP | OVERALL LENGTH | 14.000 INCHES NOMINAL |
AQHL | COMPONENT NAME | POWER SUPPLY ASSEMBLY |
AMKG | POWER UNIT TYPE | SILICON CONTROLLED RECTIFIER SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 105.0 AC POUNDS PER HOUR DRY 2ND ALTERNATE OPERATING POWER RQMT AND 127.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 2ND ALTERNATE OPERATING POWER RQMT |
APPA | III OUTPUT VOLTAGE RATING | 14.2 DC VOLTS MINIMUM AND 15.7 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
APPA | III OUTPUT VOLTAGE RATING | 24.7 DC VOLTS MINIMUM AND 27.3 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
APPA | III OUTPUT VOLTAGE RATING | 4.7 DC VOLTS MINIMUM AND 5.2 DC VOLTS MAXIMUM 4TH POWER OUTPUT |
CWKG | VENTILATION DESIGN TYPE | CONVECTION |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote