Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-00-134-5604 Item Description: Power Supply | 6130 | 001345604 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Lqd-423-2937 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 10.094 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 5.188 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 8.375 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 105.0 AC POUNDS PER HOUR DRY AND 132.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 0.0 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 120.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 0.0 DC VOLTS MINIMUM 2ND POWER OUTPUT AND 60.0 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | +0.1 TO 60.0 DEG CELSIUS |
BGHX | OUTPUT CONTROL QUANTITY | 2 1ST POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 2 2ND POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 2 3RD POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | COARSE VOLTAGE ADJUSTMENT 1ST POWER OUTPUT AND COARSE CURRENT ADJUSTMENT 1ST POWER OUTPUT AND FINE CURRENT ADJUSTMENT 1ST POWER OUTPUT AND FINE VOLTAGE ADJUSTMENT 1ST POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | COARSE VOLTAGE ADJUSTMENT 2ND POWER OUTPUT AND COARSE CURRENT ADJUSTMENT 2ND POWER OUTPUT AND FINE CURRENT ADJUSTMENT 2ND POWER OUTPUT AND FINE VOLTAGE ADJUSTMENT 2ND POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | COARSE VOLTAGE ADJUSTMENT 3RD POWER OUTPUT AND COARSE CURRENT ADJUSTMENT 3RD POWER OUTPUT AND FINE CURRENT ADJUSTMENT 3RD POWER OUTPUT AND FINE VOLTAGE ADJUSTMENT 3RD POWER OUTPUT |
BHQN | RECTIFICATION METHOD | SINGLE PHASE FULL WAVE CENTER TAP |
CBBL | FEATURES PROVIDED | FILTER |
CWGH | OUTPUT CURRENT RATING | -400.0 DC MILLIAMPERES MINIMUM 3RD POWER OUTPUT AND -700.0 DC MILLIAMPERES MAXIMUM 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 400.0 DC MILLIAMPERES MINIMUM 2ND POWER OUTPUT AND 700.0 DC MILLIAMPERES MAXIMUM 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 800.0 DC MILLIAMPERES MINIMUM 1ST POWER OUTPUT AND 1.4 DC AMPERES MAXIMUM 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 3RD POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | BINDING POST 1ST POWER OUTPUT AND TERMINAL STRIP 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | BINDING POST 2ND POWER OUTPUT AND TERMINAL STRIP 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | BINDING POST 3RD POWER OUTPUT AND TERMINAL STRIP 3RD POWER OUTPUT |
LQD 422 | LQD40A48-3V31V5REJ | LQD-421 | LQD25A48-5V03V3REJ |
LQD40A48-3V32V5REJ | LQD2K | LQD40A48-3V31V8REJ | LQD-424 |
LQD40A48-3V31V2REJ |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote