Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-703-0978 Item Description: Relay Electromagnet | 5945 | 007030978 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
A-700ay | 2 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 4.000 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 4.000 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 4.000 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.191 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.201 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
AKDX | WINDING QUANTITY | 5 |
APCN | COIL QUANTITY | 5 |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION AND 1 POLE, SINGLE THROW, NORMALLY CLOSED, DOUBLE BREAK, MOMENTARY ACTION |
CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES DC INDUCTIVE LOAD |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES DC RESISTIVE LOAD |
TTQY | TERMINAL TYPE AND QUANTITY | 7 THREADED STUD ALL FUNCTIONS |
CBBL | FEATURES PROVIDED | LATCHING CONTACTS |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
A-700182-1 | A-7000 REV J1 | A-700182-1 | A 700 DA REV 6 |
A-7-13.75-P22 24 | A-7 8NL436-1 | A-7-13.75-P22 24 | A-700 |
A-7-104 | A 7 8NL220 1 376 | A-700068 | A-70-4636 |
A-700182-1 | A-7-X-2159 | A-700121 | A-70-4636 |