Note : We Will Not Share Your Information To Any Third Parties.
MRC | Criteria | Characteristic |
---|---|---|
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
ABPM | BODY DIAMETER | 0.109 INCHES NOMINAL |
AEFB | POWER DISSIPATION RATING IN WATTS | 0.125 FREE AIR |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 165.0 |
TEST | TEST DATA DOCUMENT | 99251-1624935 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
SR-5 | MANUFACTURERS CODE | 99251 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 70.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 165.0 |
SR-5 | DESIGN CONTROL REFERENCE | 1624935-336 |
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -500.0 TO 200.0 |
SR-5 | THE MANUFACTURERS DATA | |
AARB | TERMINAL TYPE | WIRE LEAD |
AAPP | ELECTRICAL RESISTANCE | 30.900 KILOHMS |
ADAQ | BODY LENGTH | 0.250 INCHES NOMINAL |
RN50-04020 | RN5-1K | RN5-1K | RN50-01620 |
RN50-00100 | RN5-0R1K | RN50-02740 | RN50-01000 |
RN5-1K | RN50 03320 | RN50-03320 | RN50-00100 |
RN5-1K | RN50-00511 | RN50-01300 | RN50-02740 |