Note : We Will Not Share Your Information To Any Third Parties.
MRC | Criteria | Characteristic |
---|---|---|
CWWY | POWER SUPPLY EFFICIENCY LINE | 99.0 |
CWGW | POWER SUPPLY OUTPUT CURRENT/VOLTAGE CHARACTERISTICS | CONSTANT CURRENT AND CONSTANT VOLTAGE SINGLE POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 2200.0 AC VOLT-AMPERE NOMINAL SINGLE POWER OUTPUT |
BGQR | OUTPUT WATTAGE RATING | 1600.0 WATTS NOMINAL SINGLE POWER OUTPUT |
CWGN | OUTPUT PHASE | SINGLE SINGLE POWER OUTPUT |
CWGS | OUTPUT WAVEFORM AND CURRENT TYPE | FULL WAVE RECTIFIED SINE WAVE AC SINGLE POWER OUTPUT |
CWKM | WARM UP TIME IN MINUTES | 0 |
CWHM | INPUT CURRENT RATING | 16.0 DC AMPERES MINIMUM AND 17.6 DC AMPERES MAXIMUM SINGLE OPERATING POWER RQMT |
SPCL | SPECIAL TEST FEATURES | TESTED TO UL1778(USA),CSA(CANADA),NOM(MEXICO),CLASS A(EMISSIONS) FCC PART 68/INDUSTRY CANADA,ROHS COMPLIANT |
CWHY | BATTERY FEATURE AND TYPE | RECHARGEABLE LEAD ACID CELL |
CBBL | FEATURES PROVIDED | REVERSE VOLTAGE PROTECTION AND REMOTE ERROR SENSING CAPABILITY |
CWKG | VENTILATION DESIGN TYPE | SINGLE FAN |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL SINGLE POWER OUTPUT |
CWWB | BATTERY RECOVERY TIME | 5.0 |
CWWJ | PROGRAM COMPATIBILITY | WATCHDOG COMPATIBILITY |
CWWZ | POWER SUPPLY EFFICIENCY BATTERY | 99.0 |
CWJF | BATTERY LOCATION | EXTERNAL |
CXMX | BATTERY POWER SUPPLY EMERGENCY OPERATING TIME | 4.5 AND 14.0 |
ABMK | OVERALL WIDTH | 9.000 INCHES NOMINAL |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER LUG SINGLE POWER OUTPUT |
ABHP | OVERALL LENGTH | 19.500 INCHES NOMINAL |
CWHT | INPUT CONNECTION QUANTITY | 1 SINGLE OPERATING POWER RQMT |
BGHX | OUTPUT CONTROL QUANTITY | 1 SINGLE POWER OUTPUT |
ASCX | LOAD TYPE | RESISTIVE SINGLE POWER OUTPUT |
FEAT | SPECIAL FEATURES | BLACK SMART ONLINE EXPANDABLE TOWER UPS SYSTEM |
AEAS | MAJOR COMPONENTS | ON-LINE DOUBLE-CONVERSION UPS TOWER SYSTEM;SIMULTANEOUS COMMUNICATIONS VIA HID-COMPLIANT USB PORT,SERIAL PORT AND SNMP/WEB SLOT CARD;FAULT-TOLERANT AUTO-BYPASS |
AGAV | III END ITEM IDENTIFICATION | MISSION-CRITICAL APPLICATIONS |
CXCY | III PART NAME ASSIGNED BY CONTROLLING AGENCY | UPS SYSTEM TOWER |
APTS | OUTPUT FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM SINGLE POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | CONNECTOR, PLUG SINGLE OPERATING POWER RQMT |
ANRQ | FREQUENCY REGULATION PERCENT | 2.0 SINGLE POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 7 SINGLE POWER OUTPUT |
ADZC | ENVIRONMENTAL PROTECTION | MAGNETIC SHIELD AND DRIPPROOF |
ABKW | OVERALL HEIGHT | 10.250 INCHES NOMINAL |
AEXR | BATTERY QUANTITY | 1 |
APTQ | INPUT FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE RANGE SINGLE POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 110.0 AC VOLTS MINIMUM AND 120.0 AC VOLTS MAXIMUM SINGLE POWER OUTPUT |
APNX | INPUT VOLTAGE RATING | 110.0 DC VOLTS MINIMUM AND 120.0 DC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
AMNE | OUTPUT IMPEDANCE RATING | 9.0 OHMS NOMINAL SINGLE POWER OUTPUT |
SU2000R3X155 | SU2005A-SCC | SU200RMNET | SU2039 |
SU200RMNET | SU20205 | SU20170 | SU2030 |
SU20170 | SU204 | SU2039 | SU2000RMXL157 |
SU2000RMXLX157 | SU2000R3X155 | SU203M Z2 | SU2005A-FCC |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote