Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-660-6930 Item Description: Resistor Thermal | 5905 | 006606930 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | U | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
0839-0008 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 1.250 INCHES NOMINAL |
ABJT | TERMINAL LENGTH | 1.250 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.000 INCHES NOMINAL |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.625 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 0.312 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 0.875 INCHES NOMINAL |
AEBT | TERMINAL DIAMETER | 0.024 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.125 INCHES NOMINAL |
AEHX | MAXIMUM POWER DISSIPATION RATING | 3.00 WATTS |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 125.0 DEG CELSIUS |
AEHZ | MAXIMUM OPERATING TEMP | 200.0 DEG CELSIUS |
AEJA | THERMAL TIME CONSTANT IN SECONDS | 80.0 |
AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 9.0 |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 18.0 OHMS 1ST RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.0/+10.0 ALL RESISTANCE-TEMPERATURE POINTS |
AEWK | MAXIMUM CURRENT RATING | 25.00 AMPERES |
AKNA | INCLOSURE TYPE | ENCASED |
CQWD | III ZERO POWER RESISTANCE | 1.000 KILOHMS |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -5.0/+5.0 |
CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0 |
STYL | STYLE DESIGNATOR | DISK ON SURFACE PLATE |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
083-00329-01 | 083-002-039-0 | 083-0033-00 | 083-0044-006 |
083-0003-32 | 083-0030-00 | 083-0033-00 | 083 0024 00T2 |
083-0034-00 | 083-0030-00 | 083-0033-00 | 083-000927 |
083-0044 | 083-0009-00R4 | 083-0034-00 | 083-0026-00 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote