NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-519-2068 Item Description: Circuit Breaker | 5925 | 015192068 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Bacc18x15 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ADAQ | BODY LENGTH | 1.152 INCHES MAXIMUM |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 SINGLE LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.4688 INCHES |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB W/SCREW |
THSD | THREAD SERIES DESIGNATOR | UNS |
AKPX | POLE QUANTITY | 1 |
PKWT | III UNPACKAGED UNIT WEIGHT | 0.150 POUNDS |
ADAT | BODY WIDTH | 0.750 INCHES MAXIMUM |
CMLP | THREAD QUANTITY PER INCH | 32 |
ADTV | CASE MATERIAL | PLASTIC |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES AC AND 15.0 AMPERES DC SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.704 INCHES NOMINAL |
AGAV | III END ITEM IDENTIFICATION | BOEING B757 AIRCRAFT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
FREQ | FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 200.0 AC AND 28.0 DC SINGLE LOCATION |
ABXD | BUSHING LENGTH | 0.250 INCHES MAXIMUM |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
AAQL | BODY STYLE | SINGLE POLE TYPE |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 15.000 MINIMUM AT 200 PCT AND 55.000 MAXIMUM AT 200 PCT AND 2.000 MINIMUM AT 400 PCT AND 7.000 MAXIMUM AT 400 PCT AND 1.000 MINIMUM AT 600 PCT AND 3.500 MAXIMUM AT 600 PCT SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2800.0 AC AND 4800.0 DC SINGLE LOCATION |
FEAT | SPECIAL FEATURES | THREAD CLASS 2A; BARRIER EXTENDS FROM BOTTOM OF BREAKER 0.500 INCH, LENGTH IS 1.218 INCHES NOMINAL, AND THICKNESS IS 0.031 INCH NOMINAL |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.860 INCHES MAXIMUM |
BAC-100-25RCFF | BAC-211 | BAC-21 | BAC-160-25RC-FF |
BAC-21B | BAC-100-25RCSS | BAC 1520-1200 | BAC-28 |
BAC-22 | BAC 1520-1063 | BAC 3106-10 | BAC-23 |
BAC-15-25-FFC | BAC-200-25 | BAC-23 | BAC-100-25RCSS |