5985-00-160-5464 Item Description: Switch Radio Freque | 5985 | 001605464 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
012248-0001 | 6 | 1 | C |
MRC | Criteria | Characteristic |
---|---|---|
RADIO FREQUENCY TRAN | AAJD | THREAD CLASS2B MOUNTING FACILITY HOLE |
RADIO FREQUENCY TRAN | AAQL | BODY STYLEIRREGULAR |
RADIO FREQUENCY TRAN | ABHP | OVERALL LENGTH3 096 INCHES NOMINAL |
RADIO FREQUENCY TRAN | ABKW | OVERALL HEIGHT1 938 INCHES NOMINAL |
RADIO FREQUENCY TRAN | ABMK | OVERALL WIDTH1 500 INCHES NOMINAL |
RADIO FREQUENCY TRAN | ACZB | FREQUENCY RATING0 0 GIGAHERTZ MINIMUM AND 2 0 GIGAHERTZ MAXIMUM SINGLE FREQUENCY CROSSTALK REFERENCE |
RADIO FREQUENCY TRAN | AEEA | SWITCH TYPETRANSFER |
RADIO FREQUENCY TRAN | AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS1 032 INCHES NOMINAL SINGLE MOUNTING FACILITY PATTERN |
RADIO FREQUENCY TRAN | AFGA | OPERATING TEMP RANGE-55 0 TO 100 0 DEG CELSIUS |
RADIO FREQUENCY TRAN | AHTW | VOLTAGE STANDING WAVE RATIO1 20 SINGLE |
RADIO FREQUENCY TRAN | AHTX | INSERTION LOSS IN DECIBELS0 15 SINGLE |
RADIO FREQUENCY TRAN | AHUC | COAXIAL CONNECTOR SERIES DESIGNATIONN |
RADIO FREQUENCY TRAN | AHUD | CONNECTOR END DESIGNFEMALE |
RADIO FREQUENCY TRAN | AKNF | RF POWER HANDLING CAPABILITY3 0 KILOWATTS PEAK SINGLE |
RADIO FREQUENCY TRAN | AKNV | MINIMUM CROSSTALK RATING IN DECIBELS25 0 SINGLE |
RADIO FREQUENCY TRAN | AKPC | ACTUATOR OPERATING METHODRELAY |
RADIO FREQUENCY TRAN | AKPE | ACTUATOR CURRENT TYPE AND RATING IN AMPS0 1 DC MAXIMUM |
RADIO FREQUENCY TRAN | AKPJ | ACTUATOR VOLTAGE IN VOLTS26 0 NOMINAL |
RADIO FREQUENCY TRAN | AKPN | SWITCH OPERATION SEQUENCEBREAKS BEFORE MAKES |
RADIO FREQUENCY TRAN | AKPP | SWITCHING TIME25 0 MILLISECONDS |
RADIO FREQUENCY TRAN | AKPQ | SWITCH RETURN MECHANISM TYPEFAIL-SAFE |
RADIO FREQUENCY TRAN | AKQA | RF MAXIMUM VOLTAGE RATING1 0 KILOVOLTS PEAK |
RADIO FREQUENCY TRAN | AKRC | COUPLING POSITION QUANTITY4 |
RADIO FREQUENCY TRAN | AXHR | MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE |
RADIO FREQUENCY TRAN | CQJX | NOMINAL THREAD SIZE0 112 INCHES MOUNTING FACILITY HOLE |
RADIO FREQUENCY TRAN | CQYJ | MOUNTING FACILITY PATTERNTWO POSITION IN-LINE SINGLE MOUNTING FACILITY PATTERN |
RADIO FREQUENCY TRAN | MATT | MATERIALALUMINUM BODY |
RADIO FREQUENCY TRAN | SFTT | SURFACE TREATMENTENAMEL BODY OUTSIDE SURFACES |
RADIO FREQUENCY TRAN | THSD | THREAD SERIES DESIGNATORUNC MOUNTING FACILITY HOLE |
RADIO FREQUENCY TRAN | TTQY | TERMINAL TYPE AND QUANTITY2 TURRET AND 4 RECEPTACLE COAXIAL |