NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-01-255-4968 Item Description: Capacitor Fixed Ele | 5910 | 012554968 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
99194448 | B | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | W/O MTG FACILITIES, AXIAL TERMINALS |
AARF | MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR | N-4 |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.001 |
ABJT | TERMINAL LENGTH | 1.500 INCHES NOMINAL |
ABPM | BODY DIAMETER | 0.351 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.786 INCHES NOMINAL |
AEBT | TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL |
AECE | ANODE TYPE | SOLID |
AECQ | ELECTRICAL POLARIZATION | POLARIZED |
CQBQ | CAPACITANCE VALUE PER SECTION | 100.000 MICROFARADS SINGLE SECTION |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
CQLH | DC LEAKAGE AT MAXIMUM OPERATING TEMP | 200.0 MICROAMPERES |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 20.0 DC SINGLE SECTION |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CRTP | TOLERANCE RANGE PER SECTION | -10.00/+10.00 PERCENT SINGLE SECTION |
CWJK | CASE MATERIAL | METAL |
CWNJ | CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 8.000 |
CWQH | DC LEAKAGE AT REFERENCE TEMP | 10.000 MICROAMPERES |
CWSZ | CASE INSULATION MATERIAL | PLASTIC |
FEAT | SPECIAL FEATURES | WEIBULL GRADED FAILURE RATE |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-39003 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-C-39003/1 GOVERNMENT SPECIFICATION |
991-001 | 991-001-2000 | 991-007 | 991-0024-006 |
991-0014073 | 991-0020-003 | 991-0024-006 | 991-004 |
991-0014 | 991-000-00095-01 | 991-006 | 991-00004 |
991 0077 | 991 00147 | 991-00004 | 991-006 |