5905-00-858-3889 Item Description: Resistor Variable W | 5905 | 008583889 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
151-20k | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | RECTANGULAR W/MOUNTING HOLES |
ABJT | TERMINAL LENGTH | 0.172 INCHES MINIMUM AND 0.202 INCHES MAXIMUM |
ABKW | III OVERALL HEIGHT | 0.375 INCHES NOMINAL |
ABMK | III OVERALL WIDTH | 0.175 INCHES MINIMUM AND 0.195 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.072 INCHES MINIMUM AND 0.082 INCHES MAXIMUM |
ABWV | SHAFT DIAMETER | 0.091 INCHES MINIMUM AND 0.095 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.395 INCHES MINIMUM AND 0.415 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.175 INCHES MINIMUM AND 0.195 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.375 INCHES NOMINAL |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
AGTP | LATERAL DISTANCE BETWEEN MOUNTING HOLE CENTERS | 0.375 INCHES NOMINAL |
AXGY | MOUNTING METHOD | UNTHREADED HOLE |
AYQR | CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS | 0.100 INCHES NOMINAL |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -5.0 TO 5.0 SINGLE SECTION |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | III OVERALL LENGTH | 0.632 INCHES MINIMUM AND 0.702 INCHES MAXIMUM |
ABXF | SHAFT LENGTH | 0.065 INCHES MINIMUM AND 0.085 INCHES MAXIMUM |
AEDX | SHAFT STYLE | ROUND, SLOTTED |
AKPV | MOUNTING FACILITY QUANTITY | 2 |
APXH | TERMINAL LOCATION | REAR END |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 25.0 KILOHMS SINGLE SECTION |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 175.0 SINGLE SECTION |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -50.0 TO 50.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.8 FREE AIR SINGLE SECTION |
151-00001-05 | 151-0 | 151-0001-022 | 151-00004 |
151-0001 | 151-0001 | 151-0001-025 | 151-0001 |
151-0001-029 | 151-0000 | 151-00001-05 | 151-0001-025 |
151-0001 | 151-0001-022 | 151-0000 | 151-00 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote