6130-01-067-1655 Item Description: Power Supply | 6130 | 010671655 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Tp1800 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 12.500 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3.500 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 8.500 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 104.0 AC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 127.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 0.0 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 20.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 0.0 DC VOLTS MINIMUM 2ND POWER OUTPUT AND 6.0 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | +0.1/+40.0 DEG CELSIUS |
BGHX | OUTPUT CONTROL QUANTITY | 1 1ST POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 2ND POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 3RD POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 1ST POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 2ND POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 3RD POWER OUTPUT |
BHQN | RECTIFICATION METHOD | SINGLE PHASE FULL WAVE CENTER TAP |
CBBL | FEATURES PROVIDED | FILTER |
CWGH | OUTPUT CURRENT RATING | -500.0 DC MILLIAMPERES NOMINAL 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 1.0 DC AMPERES MINIMUM 2ND POWER OUTPUT AND 2.5 DC AMPERES MAXIMUM 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 500.0 DC MILLIAMPERES NOMINAL 1ST POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | TOP PANEL 1ST POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | TOP PANEL 2ND POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | TOP PANEL 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 3 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 3 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 3 3RD POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | FERRULE 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | FERRULE 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | FERRULE 3RD POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | FERRULE SINGLE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 2 SINGLE OPERATING POWER RQMT |
TP1-BK | TP1-RED | TP1-331219 | TP1-BLUE |
TP1-GREEN | TP1 2-10-B-4-B-CFS | TP1-70 | TP1-70 |
TP1-7 | TP1-331219 | TP1-70 | TP1-BLACK |
TP1-H24H | TP1-7 | TP1 1KA1 | TP1-1 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote