NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-615-8627 Item Description: Relay Thermal | 5945 | 006158627 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Hm04nc28-2 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.406 INCHES MAXIMUM |
ADAV | OVERALL DIAMETER | 0.813 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
APFR | CONTACT ARRANGEMENT | SINGLE POLE, SINGLE THROW, NORMALLY CLOSED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN |
CYCS | CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 250.0 AC AND 28.0 DC |
CYCT | CONTACT MAXIMUM CURRENT RATING IN AMPS | 3.0 AC OR 1.0 DC |
CYCU | HEATER VOLTAGE RATING IN VOLTS | 28.0 |
CYCV | HEATER POWER RATING IN WATTS | 4.0 |
CYCW | DELAY TIME IN SECONDS | 1.5 FIXED OPERATE MINIMUM AND 2.5 FIXED OPERATE MAXIMUM |
TTQY | TERMINAL TYPE AND QUANTITY | 7 PIN |
HM012-091-11 | HM010070E08 | HM00-067-21 | HM0001 |
HM012-021-91 | HM010070E08 | HM012-075-09 | HM012-075-17 |
HM012-075-19 | HM0025-441-11 | HM00208C | HM00021502G |
HM012-021-81 | HM012-075-9 | HM012 075 3 | HM012-021-101 |