Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-226-5986 Item Description: Switch Thermostatic | 5930 | 012265986 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
470as-C0210-001 | 5 | 2 | 7 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | III OVERALL LENGTH | 3.062 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.234 INCHES NOMINAL |
AGSY | FLANGE OVERALL WIDTH | 1.438 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | EXPANDING SHELL |
ALAQ | MOUNTING FACILITY CIRCLE RADIUS | 0.625 INCHES NOMINAL |
AWTN | OPERATING TEMP RATING | -54.0 DEG CELSIUS MINIMUM AND 149.0 DEG CELSIUS MAXIMUM |
AXGY | MOUNTING METHOD | FLANGE AND UNTHREADED HOLE |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQYJ | MOUNTING FACILITY PATTERN | THREE POSITION CIRCULAR |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CSCF | TERMINAL TYPE | TAB, SOLDER LUG |
CTHF | CONTACT LOAD CURRENT RATING | 1.0 AMPERES RESISTIVE LOAD AND 125.0 MILLIAMPERES INDUCTIVE LOAD THIRD VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD AND 1.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 104.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 32.0 DC AT SEA LEVEL THIRD VOLTAGE |
FREQ | FREQUENCY IN HERTZ | 50.0 AND 60.0 FIRST VOLTAGE |
FREQ | FREQUENCY IN HERTZ | 50.0 AND 60.0 SECOND VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | LIQUID OR GAS |
STYL | III STYLE DESIGNATOR | CYLINDRICAL W/FLANGE |
470-0 | 470-0 PL-4796 | 470-0000-1021-00 | 470-000-282 |
470-000-063 | 470-000-063 | 470-000-282 | 470-0-PL-5394 |
470-0000-1038-00 | 470-0003 | 470-000-282 | 470-0000-1021-00 |
470-0 | 470-0 | 470-0 | 470-0003 |