Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-01-318-9540 Item Description: Capacitor Fixed Ele | 5910 | 013189540 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Cs13bj474k | B | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARF | MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR | N-4 |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010 |
ABPM | BODY DIAMETER | 0.120 INCHES MINIMUM AND 0.151 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.255 INCHES MINIMUM AND 0.317 INCHES MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.018 INCHES MINIMUM AND 0.022 INCHES MAXIMUM |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL |
AECE | ANODE TYPE | SOLID |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
CQBQ | CAPACITANCE VALUE PER SECTION | 0.470 MICROFARADS SINGLE SECTION |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
CQLH | DC LEAKAGE AT MAXIMUM OPERATING TEMP | 5.0 MICROAMPERES |
CWJK | CASE MATERIAL | METAL |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 2.000 |
CWQH | DC LEAKAGE AT REFERENCE TEMP | 0.300 MICROAMPERES |
CWSZ | CASE INSULATION MATERIAL | PLASTIC |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-C-39003/1 GOVERNMENT SPECIFICATION |
AAQL | BODY STYLE | W/O MTG FACILITIES, AXIAL TERMINALS |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 100.0 DC SINGLE SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -10.00/+10.00 PERCENT SINGLE SECTION |
ABJT | TERMINAL LENGTH | 1.250 INCHES MINIMUM AND 1.750 INCHES MAXIMUM |
AECQ | ELECTRICAL POLARIZATION | POLARIZED |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWNJ | CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
FEAT | SPECIAL FEATURES | WEIBULL GRADED FAILURE RATE |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-39003 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI |
CS1-183617 | CS1-3049 | CS1-00023-001 | CS1 3145 |
CS1-0.013.665 | CS1-3008 | CS1-3050 | CS1-3051 |
CS1 0 010 225 | CS1-3042 | CS1-00024-001 | CS1 2092 |
CS1-1 | CS1.000.120 | CS1 12 OHM 1 PERCENT | CS1.000.119 |