Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-01-170-0430 Item Description: Capacitor Fixed Ele | 5910 | 011700430 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
16250 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | W/O MTG FACILITIES, TERMINAL(S) ON ONE ENDW/O MTG FACILITIES, TERMINAL(S) ON ONE ENDW/O MTG FACILITIES, TERMINAL(S) ON ONE END |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 2.000 INCHES MINIMUM2.000 INCHES MINIMUM2.000 INCHES MINIMUM |
ABPM | BODY DIAMETER | 0.844 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.400 INCHES MAXIMUM |
AEBS | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER | 0.235 INCHES MINIMUM AND 0.315 INCHES MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.034 INCHES MINIMUM AND 0.043 INCHES MAXIMUM |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
AECQ | ELECTRICAL POLARIZATION | POLARIZED |
AGAV | END ITEM IDENTIFICATION | 5815-01-108-5633 TELEPRINTER |
CQBQ | CAPACITANCE VALUE PER SECTION | 470.000 MICROFARADS SINGLE SECTION |
CQJJ | NONDERATED OPERATING TEMP | -40.0 DEG CELSIUS MINIMUM AND 105.0 DEG CELSIUS MAXIMUM |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 25.0 DC SINGLE SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -10.00/+100.00 PERCENT SINGLE SECTION |
CWJK | CASE MATERIAL | METAL |
CWNJ | CAPACITIVE ELECTRODE MATERIAL | ALUMINUM |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 10.0000 |
CWQC | EQUIVALENT SERIES RESISTANCE AT REFERENCE TEMP IN OHMS | 0.10 |
CWQH | DC LEAKAGE AT REFERENCE TEMP | 250.000 MILLIAMPERES |
CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
CWSZ | CASE INSULATION MATERIAL | PLASTIC |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
162-00019 | 162-0004-0 | 162-00019 | 162-0004 |
162-001 | 162-00019 | 162-000-037-000 | 162-000-050R000 |
162-000-037R000 | 162-0003-000 | 162-000-050-000 | 162-0004 |
162-0004-0 | 162-002 | 162-000-925-000 | 162-0004-0 |