Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-00-489-7393 Item Description: Capacitor Fixed Ele | 5910 | 004897393 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
163d052 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | W/O MTG FACILITIES, AXIAL TERMINALS |
AARF | MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR | N-1 |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.000 INCHES MINIMUM |
ABPM | BODY DIAMETER | 0.147 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.515 INCHES MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.016 INCHES NOMINAL |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
AECE | ANODE TYPE | SOLID |
AECQ | ELECTRICAL POLARIZATION | NONPOLARIZED |
CQBQ | CAPACITANCE VALUE PER SECTION | 1.100 MICROFARADS SINGLE SECTION |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
CQLH | DC LEAKAGE AT MAXIMUM OPERATING TEMP | 18.8 MILLIAMPERES |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 35.0 DC SINGLE SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -10.00/+10.00 PERCENT SINGLE SECTION |
CWJK | CASE MATERIAL | METAL |
CWNJ | CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 4.000 |
CWQH | DC LEAKAGE AT REFERENCE TEMP | 1.500 MICROAMPERES |
CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
CWSZ | CASE INSULATION MATERIAL | PLASTIC |
TEST | TEST DATA DOCUMENT | 94756-441-1030 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
163-0-00-00-2 | 163-003-510 | 163 0008 9 | 163-0059 |
163-0-00-06 | 163-0-00-00-1 | 163-0-5000DC | 163-0-00-00-2 |
163-0-00-03 | 163-0-60 | 163-001-000 | 163-001-000-000 |
163-0-00-03 | 163-0-00-06 | 163-0007-1 | 163-0-00-00 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |