Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-01-045-6673 Item Description: Filter Radio Freque | 5915 | 010456673 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
10b609-3 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 5.620 INCHES NOMINAL |
ADAQ | BODY LENGTH | 5.000 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.000 INCHES NOMINAL |
ADAU | BODY HEIGHT | 3.500 INCHES NOMINAL |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.719 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | AN/APR-38 |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.5 1ST RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.5 2ND RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.5 3RD RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 1ST RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 2ND RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 3RD RADIO INTERFERENCE |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 6 THREADED STUD OUTPUT 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote