Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-077-0194 Item Description: Switch Thermostatic | 5930 | 000770194 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
18420-101-275 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 2A SINGLE THREADED BUSHING |
AASA | THREAD LENGTH | 0.500 INCHES NOMINAL SINGLE THREADED BUSHING |
ABFE | III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
ABHP | III OVERALL LENGTH | 5.280 INCHES NOMINAL |
ABPM | BODY DIAMETER | 0.618 INCHES MINIMUM AND 0.625 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 4.060 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | EXPANDING SHELL |
ASDB | WIDTH ACROSS FLATS | 1.000 INCHES NOMINAL |
AXGY | MOUNTING METHOD | THREADED BUSHING |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQJX | NOMINAL THREAD SIZE | 0.875 INCHES SINGLE THREADED BUSHING |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CSCF | TERMINAL TYPE | TAB W/SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE, PRESET AND DEACTUATION POINT ADJUSTABLE, PRESET |
CTYM | CONTACT ADJUSTMENT RANGE | -100.00 TO 400.00 ACTUATION POINT DEGREES FAHRENHEIT AND -100.00 TO 400.00 DEACTUATION POINT DEGREES FAHRENHEIT |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW AND EXTERNAL DEACTUATION POINT SCREW |
CTYX | CONTACT STIMULUS RATING | 275.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 263.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL THIRD VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 240.0 AC AT SEA LEVEL SECOND VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
STYL | III STYLE DESIGNATOR | CYLINDRICAL W/FLANGE |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE THREADED BUSHING |
184-001 | 184-00022-83 | 184-00044-06 | 184-0017 |
184-0013 | 184-00057-06 | 184-00021-05 | 184-00047-05 |
184 00115 05 05 | 184-00128-04 | 184-00047-05 | 184-0006 |
184-0011 | 184-0014 | 184-0002 | 184-0011 |