Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-01-476-0381 Item Description: Attenuator Fixed | 5985 | 014760381 | 0 | P | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | B | C | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
459819-11 | 5 | 2 | 7 |
MRC | Criteria | Characteristic |
---|---|---|
BNGR | FREQUENCY RANGE | 0.000 HERTZ MINIMUM AND 18.000 GIGAHERTZ MAXIMUM |
AJDK | RF SIGNAL ATTENUATION IN DECIBELS | 1.0 |
ABKW | OVERALL HEIGHT | 0.016 INCHES MINIMUM AND 0.046 INCHES MAXIMUM |
ABHP | OVERALL LENGTH | 0.078 INCHES MINIMUM AND 0.112 INCHES MAXIMUM |
AHTZ | OUTPUT IMPEDANCE RATING IN OHMS | 50.0 |
ABMK | OVERALL WIDTH | 0.059 INCHES MINIMUM AND 0.081 INCHES MAXIMUM |
AFGA | OPERATING TEMP RANGE | -55.0 TO 125.0 DEG CELSIUS |
AGAV | III END ITEM IDENTIFICATION | UNIVERSAL EXCITER UPGRADE |
FEAT | SPECIAL FEATURES | ESD SENSITIVE, 2 BONDING PADS PRETINNED, PLATINUM GOLD WRAP ON GROUND AND BOTTOM SIDE |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.30 |
AHTY | INPUT IMPEDANCE RATING IN OHMS | 50.0 |
PMLC | III PRECIOUS MATERIAL AND LOCATION | TERMINAL SURFACES GOLD AND TERMINAL SURFACES PLATINUM |
459-00 | 459-0090 | 459-0080 | 459-001 |
459-001 | 459-00VM | 459-0070 | 459-0010 |
459-000-000L005 | 459-0060 | 459-001 | 459-001 |
459-0050 | 459-001 | 459-0030 | 459-001 |