5925-01-425-4332 Item Description: Circuit Breaker | 5925 | 014254332 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
29538-1 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY FIRST LOCATION TIME DELAY SECOND LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 FIRST LOCATION 150.0 SECOND LOCATION |
CQQC | TRIP RELEASE DUTY CYCLE | CONTINUOUS SECOND LOCATION |
FREQ | FREQUENCY IN HERTZ | 50.0 OR 60.0 OR 400.0 FIRST LOCATION 50.0 OR 60.0 OR 400.0 SECOND LOCATION |
AKPX | POLE QUANTITY | 2 |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.750 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
ADAT | BODY WIDTH | 1.500 INCHES NOMINAL |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC AND 10.0 AMPERES DC FIRST LOCATION 10.0 AMPERES AC AND 10.0 AMPERES DC SECOND LOCATION |
CPRK | AUXILIARY TRIP COIL VOLTAGE TYPE AND RATING IN VOLTS | 115.0 AC NOMINAL SECOND LOCATION |
AJEC | BOSS HEIGHT | 0.130 INCHES NOMINAL |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC FIRST LOCATION 115.0 AC SECOND LOCATION |
CPRQ | RESET METHOD | MANUAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 CLIP |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.750 INCHES NOMINAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
TTQY | TERMINAL TYPE AND QUANTITY | 5 KNIFE BLADE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000.0 AC AND 1000.0 DC FIRST LOCATION 2000.0 AC AND 1000.0 DC SECOND LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP FIRST LOCATION SERIES TRIP W/REMOTE TRIP FEATURE SECOND LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT FIRST LOCATION OVERCURRENT SECOND LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC FIRST LOCATION MAGNETIC SECOND LOCATION |
ADAQ | BODY LENGTH | 2.000 INCHES NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.560 INCHES NOMINAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.950 INCHES MAXIMUM |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 6.000 MINIMUM AT 150 PCT AND 70.000 MAXIMUM AT 150 PCT FIRST LOCATION 0.400 MINIMUM AT 150 PCT AND 6.000 MAXIMUM AT 150 PCT SECOND LOCATION |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.660 INCHES NOMINAL |