6130-01-288-7987 Item Description: Power Supply | 6130 | 012887987 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
5bxmpa | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 8.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1.750 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 4.870 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE 1ST OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 2ND OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 180.0 AC POUNDS PER HOUR DRY 1ST OPERATING POWER RQMT AND 264.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 1ST OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 90.0 AC POUNDS PER HOUR DRY 2ND OPERATING POWER RQMT AND 132.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 2ND OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -12.0 DC VOLTS NOMINAL 4TH POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | -5.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | +0.1/+40.0 DEG CELSIUS |
BGHX | OUTPUT CONTROL QUANTITY | 1 1ST POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 2ND POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 3RD POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 4TH POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | FIXED VOLTAGE 1ST POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | FIXED VOLTAGE 3RD POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | FIXED VOLTAGE 4TH POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 1.5 DC AMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 250.0 DC MILLIAMPERES NOMINAL 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 500.0 DC MILLIAMPERES NOMINAL 4TH POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 7.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 4 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 4 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 4 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 4 4TH POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER STUD 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER STUD 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER STUD 3RD POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER STUD 4TH POWER OUTPUT |