Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-01-117-6248 Item Description: Capacitor Fixed Ele | 5910 | 011176248 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
M39018 03-1241m | E | 2 | 2 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | W/O MTG FACILITIES, AXIAL TERMINALS |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 1.0000 |
ABJT | TERMINAL LENGTH | 2.500 INCHES NOMINAL |
ABPM | BODY DIAMETER | 1.000 INCHES NOMINAL |
ADAQ | BODY LENGTH | 2.125 INCHES MINIMUM AND 2.328 INCHES MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.040 INCHES NOMINAL |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
AECN | IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS | 2.7 |
AECQ | ELECTRICAL POLARIZATION | POLARIZED |
CQBQ | CAPACITANCE VALUE PER SECTION | 1000.000 MICROFARADS SINGLE SECTION |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 105.0 DEG CELSIUS MAXIMUM |
CQLH | DC LEAKAGE AT MAXIMUM OPERATING TEMP | 670.0 MICROAMPERES |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 50.0 DC SINGLE SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -10.00/+30.00 PERCENT SINGLE SECTION |
CWJK | CASE MATERIAL | METAL |
CWNJ | CAPACITIVE ELECTRODE MATERIAL | ALUMINUM |
CWQC | EQUIVALENT SERIES RESISTANCE AT REFERENCE TEMP IN OHMS | 0.13 |
CWQH | DC LEAKAGE AT REFERENCE TEMP | 111.000 MICROAMPERES |
CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
CWSZ | CASE INSULATION MATERIAL | PLASTIC |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-39018 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-C-39018/3 GOVERNMENT SPECIFICATION |
M390 | M39-1000-01-0108 | M39-3 | M39-0630-10 |
M39-2 | M39-22225 | M3900 01-7015 | M3900 01-7015 |
M3900-2615 | M39-22225 | M39-22225 | M39-1000-01-0108 |
M39-0630-10 | M39-019 03-312 | M3900-2615 | M39-2 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote