NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-01-201-4844 Item Description: Resistor Fixed Film | 5905 | 012014844 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | G | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ms244-2-0meg | 2 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -50.0 TO 50.0 |
AAPP | ELECTRICAL RESISTANCE | 2.000 MEGOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -2.000 TO 2.000 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 25.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 275.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -15.0 TO 105.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARB | TERMINAL TYPE | WIRE LEAD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.500 INCHES MINIMUM |
ABPM | BODY DIAMETER | 0.230 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.950 INCHES NOMINAL |
AEFB | POWER DISSIPATION RATING IN WATTS | 4.000 FREE AIR |
AGAV | END ITEM IDENTIFICATION | SEQUENCED FLASHING LIGHT,TYPE III (SFLIII) |
PMLC | PRECIOUS MATERIAL AND LOCATION | TERMINALS GOLD |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |