Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-01-154-2491 Item Description: Filter Band Pass | 5915 | 011542491 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
526-9997-010 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.562 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 0.670 INCHES NOMINAL |
ADAR | BODY OUTSIDE DIAMETER | 0.437 INCHES NOMINAL |
ADAU | BODY HEIGHT | 1.650 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.128 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 0.750 INCHES NOMINAL |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | +10.0/+55.0 |
AFGA | OPERATING TEMP RANGE | -30.0/+85.0 DEG CELSIUS |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 501.9 SINGLE RADIO INTERFERENCE PULSES PER SECOND |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 501.9 SINGLE RADIO INTERFERENCE TWO PHASE TO TWO PHASE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST BAND PASS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND BAND PASS |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST BAND PASS |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND BAND PASS |
AHBX | DISTANCE BETWEEN MOUNTING SURFACE AND LOWER END | 0.7212 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 5.5 1ST BAND PASS |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 5.5 2ND BAND PASS |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB, SOLDER LUG GROUND 3RD FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG OUTPUT 2ND FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 499.20 KILOHERTZ 1ST BAND PASS 1ST FUNCTION AND 500.30 KILOHERTZ 1ST BAND PASS 1ST FUNCTION AND 503.50 KILOHERTZ 1ST BAND PASS 1ST FUNCTION AND 505.30 KILOHERTZ 1ST BAND PASS 1ST FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 499.20 KILOHERTZ 2ND BAND PASS 2ND FUNCTION AND 500.30 KILOHERTZ 2ND BAND PASS 2ND FUNCTION AND 503.50 KILOHERTZ 2ND BAND PASS 2ND FUNCTION AND 505.30 KILOHERTZ 2ND BAND PASS 2ND FUNCTION |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 500.30 KILOHERTZ 1ST BAND PASS AND 503.50 KILOHERTZ 1ST BAND PASS |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 500.30 KILOHERTZ 2ND BAND PASS AND 503.50 KILOHERTZ 2ND BAND PASS |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 60.0 MINIMUM 1ST BAND PASS 1ST FUNCTION AND 3.0 MAXIMUM 1ST BAND PASS 1ST FUNCTION AND 3.0 MAXIMUM 1ST BAND PASS 1ST FUNCTION AND 60.0 MINIMUM 1ST BAND PASS 1ST FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 60.0 MINIMUM 2ND BAND PASS 2ND FUNCTION AND 3.0 MAXIMUM 2ND BAND PASS 2ND FUNCTION AND 3.0 MAXIMUM 2ND BAND PASS 2ND FUNCTION AND 60.0 MINIMUM 2ND BAND PASS 2ND FUNCTION |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 100.0 VOLTS AT SEA LEVEL |
CRST | BODY SURFACE TREATMENT | TIN |
STYL | STYLE DESIGNATOR | ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |
526-00-322 | 526-0 | 526-0006 | 526-0006 |
526-0002-010 | 526-001 | 526 001 | 526-0008 |
526-0001 | 526-001 | 526-0002 | 526 0008 |
526-0006 | 526-0007 | 526-0 | 526-000-200 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote