5930-01-482-9220 Item Description: Switch Thermostatic | 5930 | 014829220 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Cd-00258 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
FEAT | SPECIAL FEATURES | USED ON AN/USQ-132 |
AXGY | MOUNTING METHOD | TERMINAL, WIRE-LEAD |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE 2.5 AMPERES RESISTIVE LOAD SECOND VOLTAGE 1.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL FIRST VOLTAGE 120.0 AC AT SEA LEVEL SECOND VOLTAGE 25.0 AC AT SEA LEVEL THIRD VOLTAGE |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CSCF | TERMINAL TYPE | QUICK DISCONNECT, MALE |
AWTN | OPERATING TEMP RATING | 10.0 DEG CELSIUS MINIMUM AND 45.0 DEG CELSIUS MAXIMUM |
STYL | STYLE DESIGNATOR | DISC |