Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-324-0762 Item Description: Switch Thermostatic | 5930 | 003240762 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
973114-1b | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | III OVERALL LENGTH | 1.240 INCHES MINIMUM AND 1.260 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 0.526 INCHES MAXIMUM |
ABPM | BODY DIAMETER | 0.605 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.390 INCHES MAXIMUM |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.937 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
AXGY | MOUNTING METHOD | BRACKET |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CSCF | TERMINAL TYPE | TAB, SOLDER LUG |
CTHF | CONTACT LOAD CURRENT RATING | 1.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 195.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 180.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL THIRD VOLTAGE |
FEAT | SPECIAL FEATURES | INCL EVACUATION TUBE |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS |
STYL | III STYLE DESIGNATOR | DISC W/FLANGE |
TEST | TEST DATA DOCUMENT | 81349-MIL-S-24236 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI |