5961-01-377-5738 Item Description: Transistor | 5961 | 013775738 | 0 | N | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
St-1648 | 5 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CTRD | POWER RATING PER CHARACTERISTIC | 5.0 WATTS MAXIMUM TOTAL DEVICE DISSIPATION |
ABBH | INCLOSURE MATERIAL | METAL |
ABJT | TERMINAL LENGTH | 0.500 INCHES MINIMUM |
CTQN | VOLTAGE RATING IN VOLTS PER CHARACTERISTIC | 400.0 MAXIMUM COLLECTOR TO BASE VOLTAGE/STATIC/EMITTER OPEN AND 400.0 MAXIMUM COLLECTOR TO EMITTER VOLTAGE/STATIC/BASE OPEN AND 5.0 MAXIMUM EMITTER TO BASE VOLTAGE, STATIC, COLLECTOR OPEN |
ADAV | OVERALL DIAMETER | 0.370 INCHES MAXIMUM |
ABHP | OVERALL LENGTH | 0.260 INCHES MAXIMUM |
AXGY | MOUNTING METHOD | TERMINAL |
CTMZ | SEMICONDUCTOR MATERIAL | SILICON |
PKWT | (NON-CORE DATA) UNPACKAGED UNIT WEIGHT | 0.042 OUNCES |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
CTSG | MAXIMUM OPERATING TEMP PER MEASUREMENT POINT | 150.0 DEG CELSIUS JUNCTION |
TTQY | TERMINAL TYPE AND QUANTITY | 3 UNINSULATED WIRE LEAD |
TEST | TEST DATA DOCUMENT | 82577-928493 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
ALAS | INTERNAL CONFIGURATION | JUNCTION CONTACT |
CTQX | CURRENT RATING PER CHARACTERISTIC | 2.50 AMPERES MAXIMUM COLLECTOR CURRENT, DC |
ALAZ | JOINT ELECTRONIC DEVICE ENGINEERING COUNCIL/JEDEC/CASE OUTLINE DESIGNATION | TO-39 |
AYQS | TERMINAL CIRCLE DIAMETER | 0.190 INCHES MINIMUM AND 0.210 INCHES MAXIMUM |
FEAT | SPECIAL FEATURES | JUNCTION PATTERN ARRANGEMENT: PNP |
ST-008-Y | ST-003-R | ST-010-B | ST-005-B |
ST-005-Y-T | ST-004-B | ST-005-B-T | ST-004-R |
ST-001-R | ST-002-B | ST-005-Y | ST-005-R-T |
ST-010-R | ST-001-B | ST-005-R | ST-010-Y |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote