Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-103-7918 Item Description: Circuit Breaker | 5925 | 001037918 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ms26574-4a | 2 | 2 | 2 |
MRC | Criteria | Characteristic |
---|---|---|
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | MOISTURE RESISTANT AND EXPLOSION RESISTANT |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25 0 DEG CELSIUS NOMINAL SINGLE LOCATION |
CRTK | SWITCH TERMINAL TYPE | TAB SOLDER LUG |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 4 0 AC AND 4 0 DC |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 115 0 AC AND 28 0 DC |
FREQ | FREQUENCY IN HERTZ | 400 0 SINGLE LOCATION |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-5809 SPECIFICATION INCLUDES ENGINEERING TYPE BULLETINS BROCHURESETC THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT EXCLUDES COMMERCIAL CATALOGS INDUSTRY DIRECTORIES AND SIMILAR TRADE PUBLICATIONS REFLECTIN |
THSD | THREAD SERIES DESIGNATOR | UN |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SCREW |
ZZZK | SPECIFICATIONSTANDARD DATA | 96906-MS26574 GOVERNMENT STANDARD |
AAQL | BODY STYLE | SINGLE POLE TYPE |
ABXD | BUSHING LENGTH | 0 359 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0 780 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0 580 INCHES MAXIMUM |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0 593 INCHES NOMINAL |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE SINGLE THROW NORMALLY CLOSED |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1 420 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 4 0 AMPERES AC AND 4 0 AMPERES DC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 115 0 AC AND 28 0 DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 100 0 AC AND 100 0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 145 0 SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 CONTROL |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQJX | NOMINAL THREAD SIZE | 0 438 INCHES |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | EXTERNAL AT POLE ONE |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2 000 MINIMUM AT 200 PCT AND 20 000 MAXIMUM AT 200 PCT SINGLE LOCATION |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote