MRC | Criteria | Characteristic |
---|---|---|
CXCB | DISCHARGE DIRECTION | HORIZONTAL AND VERTICAL UP |
CQKX | AIR FLOW RATE | 992.0 CUBIC FEET PER MINUTE NOMINAL |
AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED |
AGAV | III END ITEM IDENTIFICATION | F-15 TISS BLOWER ASSY 4140-01-567-1788 |
ABBB | SPEED ADJUSTMENTS | SINGLE SPEED |
CXCY | III PART NAME ASSIGNED BY CONTROLLING AGENCY | BLOWER, 9-1/2IN |
AJLY | STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.3 INCHES OF WATER |
FAAZ | PHASE | SINGLE |
STYL | STYLE DESIGNATOR | FIXED, INVERTED, RECTANGULAR OUTLET |
CRWJ | OUTLET LOCATION | BOTTOM OR TOP |
AKCV | DRIVE TYPE | DIRECT |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 104.0 DEG FAHRENHEIT |
MATT | MATERIAL | STEEL BLADE STEEL HOUSING |
ADZC | ENVIRONMENTAL PROTECTION | DRIPPROOF |
CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | 115.0 AC |
CWLY | PRIME MOVER DRIVE SHAFT BEARING TYPE | SLEEVE |
FREQ | FREQUENCY IN HERTZ | 60.0 |
AAYD | STAGE QUANTITY | 1 |
SFTT | SURFACE TREATMENT | PAINT OVERALL |
AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
CSYL | PRIME MOVER POWER RATING | 0.166 HORSEPOWER |
FEAT | SPECIAL FEATURES | DAYTON MODEL 5C090 WITH OUTLET EDGE SCROLLED AND 12EA 0.250IN HOLES DRILLED 0.38IN FROM EDGE |
AEQC | OPERATING SPEED AT RATED CAPACITY IN RPM | 1075.0 |