MRC | Criteria | Characteristic |
---|---|---|
ASSB | MECHANICAL CONNECTION QUANTITY | 1 |
ASSC | MECHANICAL CONNECTION SIZE | 7/16-20 UNF MALE PER MS33656-E4 |
ASSD | MECHANICAL CONNECTION TYPE | EXTERNAL THREAD AND THREAD |
AFLW | ACTUATION METHOD | PRESSURE SENSING ELEMENT |
ADAV | OVERALL DIAMETER | 1.250 INCHES NOMINAL |
ACDC | CURRENT TYPE | DC |
AFRA | CONTACT QUANTITY | 6 |
ASKX | ELECTRICAL CONNECTION QUANTITY | 1 |
ABHP | OVERALL LENGTH | 4.980 INCHES NOMINAL |
AGAV | III END ITEM IDENTIFICATION | NSN 4920-01-136-2857 TEST SYSTEM AUTOMATED GROUND ENGINE F15/16 ACFT |
AMSE | VOLTAGE RATING | 28.0 VOLTS NOMINAL INPUT 1.0 VOLTS MINIMUM AND 9.0 VOLTS MAXIMUM OUTPUT |
AXGY | MOUNTING METHOD | EXTERNAL THREAD |
BHMW | MEASUREMENT RANGE | 0.0 TO 100.0 POUNDS PRESSURE PER SQUARE INCH |
ASKZ | ELECTRICAL CONNECTION IDENTIFYING NUMBER | PTIH-10-6P OR EQUIV. |
FEAT | SPECIAL FEATURES | ACCURACY 0.1% F.S.; COMP. TEMP RANGE -18 DEG C TO 65 DEG C; MAX TEMP RANGE -54 DEG C TO 93 DEG C; INPUT VOLTAGE 28 VDC, 20 MA; 6 MONTH STABILITY 0.15% F.S.;RANGE 0 TO 100 PSI ABSOLUTE |
AKSF | CONTACT TYPE | PIN |
ASKY | ELECTRICAL CONNECTION CONTROLLING AGENCY | BENDIX |
ACUP | MOUNTING DEVICE QUANTITY | 1 |