5905-00-056-9845 Item Description: Resistor Thermal | 5905 | 000569845 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | U | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
714-1728-00 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.000 INCHES MINIMUM |
ADAQ | BODY LENGTH | 0.625 INCHES MAXIMUM |
ADAR | BODY OUTSIDE DIAMETER | 0.219 INCHES MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.032 INCHES NOMINAL |
AEHX | MAXIMUM POWER DISSIPATION RATING | 1.00 WATTS |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
AEHZ | MAXIMUM OPERATING TEMP | 150.0 DEG CELSIUS |
AEJA | THERMAL TIME CONSTANT IN SECONDS | 25.0 |
AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 11.0 |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 70.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 90.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 11.8 OHMS 1ST RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 13.5 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 14.3 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -1.0/+1.0 ALL RESISTANCE-TEMPERATURE POINTS |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
CQWD | III ZERO POWER RESISTANCE | 10.000 OHMS |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0/+10.0 |
CTGT | III REFERENCE TEMP IN DEG CELSIUS | 25.0 |
STYL | STYLE DESIGNATOR | ROD |
TEST | TEST DATA DOCUMENT | 13499-714-1728-000 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
714-000-001 | 714-001-000 | 714-0007-010 | 714-0007-030 |
714-0007-010 | 714 00026 00 0 | 714-001-000 | 714-00 |
714-00018-01-0 | 714-00018-00-0 | 714-00026-00 | 714 00018 01 |
714-0007-030 | 714-00018-00 | 714-001 | 714-0010 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote