Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-402-1010 Item Description: Resistor Variable N | 5905 | 004021010 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | U | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Yr103u | 2 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | CYLINDRICAL |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | III OVERALL LENGTH | 0.906 INCHES NOMINAL |
ABJT | TERMINAL LENGTH | 0.547 INCHES NOMINAL |
ABPM | BODY DIAMETER | 0.500 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.359 INCHES NOMINAL |
ADAV | III OVERALL DIAMETER | 0.500 INCHES NOMINAL |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 295.0 NOMINAL |
AEFK | MAXIMUM STARTING TORQUE | 3.00 INCH-OUNCES |
AEFL | MAXIMUM RUNNING TORQUE | 0.25 INCH-OUNCES |
AEFM | MAXIMUM STOP TORQUE | 32.00 INCH-OUNCES |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
APXH | TERMINAL LOCATION | REAR END |
AXGY | MOUNTING METHOD | TERMINAL |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 10.0 KILOHMS SINGLE SECTION |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 295.0 NOMINAL |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
CQDB | RESISTANCE TEMP CHARACTERISTIC RANGE PER SECTION IN PERCENT | +0.0 TO 7.0 -55 DEG CELSIUS SINGLE SECTION AND +0.0 TO 3.5 -25 DEG CELSIUS SINGLE SECTION AND +0.0 TO 2.0 0 DEG CELSIUS SINGLE SECTION AND -2.5 TO 2.5 85 DEG CELSIUS SINGLE SECTION AND +0.0 TO 5.5 120 DEG CELSIUS SINGLE SECTION |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 120.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.25 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0 TO 10.0 SINGLE SECTION |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 70.0 SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
YR1073 | YR102U | YR10539 | YR1-1 2XC |
YR1 1 2XC | YR101U | YR101M | YR1072 |
YR107 | YR10266 | YR1 3 8 3 | YR10541 |
YR101U | YR102U | YR107 | YR104M |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |