Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-007-7272 Item Description: Resistor Variable N | 5905 | 000077272 | 0 | N | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | U | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
719110-47 | 3 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | CYLINDRICAL BUSHING MOUNTED |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | III OVERALL LENGTH | 2.166 INCHES MAXIMUM |
ABNB | FIRST FLAT LENGTH | 0.625 INCHES NOMINAL |
ABNC | FLAT HEIGHT | 0.211 INCHES MINIMUM AND 0.221 INCHES MAXIMUM |
ABPM | BODY DIAMETER | 1.031 INCHES MINIMUM AND 1.157 INCHES MAXIMUM |
ABWV | SHAFT DIAMETER | 0.248 INCHES MINIMUM AND 0.251 INCHES MAXIMUM |
ABXF | SHAFT LENGTH | 1.375 INCHES NOMINAL |
ADAP | MOUNTING BUSHING LENGTH | 0.359 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.460 INCHES MINIMUM AND 0.750 INCHES MAXIMUM |
ADAV | III OVERALL DIAMETER | 1.515 INCHES MAXIMUM |
AEDX | SHAFT STYLE | ROUND, FLATTED |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 312.0 NOMINAL |
AEFK | MAXIMUM STARTING TORQUE | 6.00 INCH-OUNCES |
AEFL | MAXIMUM RUNNING TORQUE | 1.00 INCH-OUNCES |
AEFM | MAXIMUM STOP TORQUE | 192.00 INCH-OUNCES |
AEFN | NONTURN DEVICE LOCATION | AT 9 OCLOCK |
AEFP | NONTURN DEVICE RADIUS | 0.546 INCHES MAXIMUM |
AJYN | SCREW THREAD DIAMETER | 0.375 INCHES NOMINAL |
AJYP | SCREW THREAD SERIES DESIGNATOR | UNEF |
AJYQ | SCREW THREAD QUANTITY PER INCH | 32.0 |
APXH | TERMINAL LOCATION | RADIALLY POSITIONED OVER LESS THAN HALF THE CIRCUMFERENCE |
AXGY | MOUNTING METHOD | STANDARD BUSHING W/PANEL SEAL |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 50.0 KILOHMS SINGLE SECTION |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 312.0 NOMINAL |
CQDB | RESISTANCE TEMP CHARACTERISTIC RANGE PER SECTION IN PERCENT | +0.0 TO 7.0 -55 DEG CELSIUS SINGLE SECTION AND +0.0 TO 3.5 -25 DEG CELSIUS SINGLE SECTION AND +0.0 TO 2.0 0 DEG CELSIUS SINGLE SECTION AND -2.5 TO 2.5 85 DEG CELSIUS SINGLE SECTION AND +0.0 TO 5.5 120 DEG CELSIUS SINGLE SECTION |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 120.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 2.25 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0 TO 10.0 SINGLE SECTION |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 70.0 SINGLE SECTION |
TEST | TEST DATA DOCUMENT | 05869-719110 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
TTQY | TERMINAL TYPE AND QUANTITY | 3 TAB, SOLDER LUG |
719-0001 | 719-0001 | 719-0002-3 | 719-005 |
719-0050-001 | 719-00404 | 719-0002 | 719-0017 |
719-005 | 719-00-48 | 719-0002-9 | 719-0001-010 |
719-00-63 | 719-0002-9 | 719 00103 | 719-005 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote