Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-330-8659 Item Description: Transformer Power | 5950 | 013308659 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
20737 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.140 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.160 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 1.775 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.600 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 16.7 KILOHERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 115.12 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 20.93 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 41.85 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 13 TURRET |
CWJS | WINDING OPERATING VOLTAGE | 150.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 20.93 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
ABHP | OVERALL LENGTH | 3.150 INCHES MAXIMUM |
FEAT | SPECIAL FEATURES | TERMINAL 17 IS INTERNALLY CONNECTED TO TERMINAL 3; TERMINAL 18 IS INTERNALLY CONNECTED TO TERMINAL 1; TERMINAL 19 IS INTERNALLY CONNECTED TO TERMINAL 2; TERMINAL 13 AND 14 ARE INTERNALLY CONNECTED DUMMY TERMINALS |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.590 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.610 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
207-000-101 | 207-000-121 | 207-000-135 | 207 00 STEEL |
207-000-107 | 207-000-119 | 207-000-1 | 207-000-113 |
207-000-111 | 207-000-127 | 207 000 | 207-000-105 |
207-000-109 | 207-000 | 207-000-117 | 207-000 |