Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-219-5092 Item Description: Power Supply | 6130 | 012195092 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
351st | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 11.120 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1.680 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 5.290 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF AND EXPLOSION PROOF AND FUNGUS PROOF AND SALT SPRAY RESISTANT AND SHOCK PROOF |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
AMQY | INSTALLATION DESIGN | BENCH OR BRACKET |
ANPM | INPUT PHASE | SINGLE 1ST OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 2ND OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 105.0 DC POUNDS PER HOUR DRY 1ST OPERATING POWER RQMT AND 130.0 DC POUNDS PER HOUR WITH RETAINING CHAIN 1ST OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 198.0 DC POUNDS PER HOUR DRY 2ND OPERATING POWER RQMT AND 265.0 DC POUNDS PER HOUR WITH RETAINING CHAIN 2ND OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 24.0 DC VOLTS MINIMUM SINGLE POWER OUTPUT AND 28.0 DC VOLTS MAXIMUM SINGLE POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 1000.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 1000.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | -40.0/+80.0 DEG CELSIUS |
CWGH | OUTPUT CURRENT RATING | 5.0 DC AMPERES NOMINAL SINGLE POWER OUTPUT |
CWGZ | RIPPLE VOLTAGE AT FULL LOAD | 100.0 MILLIVOLTS AVERAGE SINGLE POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP SINGLE POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP 1ST OPERATING POWER RQMT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP 2ND OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 1ST OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 2ND OPERATING POWER RQMT |
FEAT | SPECIAL FEATURES | ALL INPUT AND OUTPUT CONNECTIONS ARE ON ONE BARRIER TYPE TERMINAL STRIP |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.