Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-00-323-1078 Item Description: Filter Radio Freque | 5915 | 003231078 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Rme-F-0398 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ADAQ | BODY LENGTH | 4.100 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.250 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 2.850 INCHES MAXIMUM |
AFGA | OPERATING TEMP RANGE | -54.0/+105.0 DEG CELSIUS |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 4TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.0 1ST RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.0 2ND RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.0 3RD RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.0 4TH RADIO INTERFERENCE |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED HOLE |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
RME-95-101 | RME-0F-0176 | RME-1000-50 | RME 1000 16 |
RME-A-303-L | RME-5-25 | RME-96-325 | RME-95-101 |
RME-F-0007 | RME-D-J-010 | RME-5-25 | RME 2P 67S 33C4 S03 |
RME-A8972AO | RME-F-0007 | RME-0F-0176 | RME-D-J-010 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote