Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5962-01-381-5575 Item Description: Microcircuit Digita | 5962 | 013815575 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | A | 8 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Lia3055 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ADAQ | BODY LENGTH | 1.080 INCHES MINIMUM AND 1.135 INCHES MAXIMUM |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
FEAT | SPECIAL FEATURES | ESD;INPUT CURRENT IS PORM 10 MIL LIAMPERES |
AFGA | OPERATING TEMP RANGE | -55.0 TO 125.0 DEG CELSIUS |
SR-1 | MFR SOURCE CONTROLLING REFERENCE | 654729-1 |
AGAV | III END ITEM IDENTIFICATION | AIM-120 |
SR-1 | SPEC/STD CONTROLLING DATA | |
CBBL | FEATURES PROVIDED | BURN IN, MIL-STD-883, CLASS B AND TESTED TO MIL-STD-883 AND ELECTROSTATIC SENSITIVE |
ADAT | BODY WIDTH | 1.080 INCHES MINIMUM AND 1.135 INCHES MAXIMUM |
AFJQ | STORAGE TEMP RANGE | -65.0 TO 150.0 DEG CELSIUS |
CQSZ | INCLOSURE CONFIGURATION | PIN GRID ARRAY |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | MICROCIRCUIT DIGITAL 8370 GATE ARRAY, CMOS LSI RC CORRELATION |
TEST | TEST DATA DOCUMENT | 96906-MIL-STD-883 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). |
CTQX | CURRENT RATING PER CHARACTERISTIC | 10.00 MILLIAMPERES MAXIMUM INPUT |
CQWX | OUTPUT LOGIC FORM | COMPLEMENTARY-METAL OXIDE-SEMICONDUCTOR LOGIC |
ADAU | BODY HEIGHT | 0.080 INCHES MINIMUM AND 0.120 INCHES MAXIMUM |
CZEN | VOLTAGE RATING AND TYPE PER CHARACTERISTIC | -0.3 VOLTS MINIMUM TOTAL SUPPLY AND 7.0 VOLTS MAXIMUM TOTAL SUPPLY AND -0.3 VOLTS MINIMUM INPUT AND 0.3 VOLTS MAXIMUM INPUT |
TTQY | TERMINAL TYPE AND QUANTITY | 84 PIN |
SR-1 | MANUFACTURERS CODE | 82577 |
CSSL | DESIGN FUNCTION AND QUANTITY | 1 GATE, ARRAY |
LIA100P | LIA130STR | LIA 1515 | LIA100PTR |
LIA1620 | LIA100 | LIA130 | LIA120S |
LIA120 | LIA100-F | LIA130S | LIA101PTR |
LIA120STR | LIA0681 | LIA0681 | LIA 1515 |