5985-00-646-5300 Item Description: Coupler Directional | 5985 | 006465300 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
26371 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 18.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 9.250 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 17.030 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | AN/FPS-20 |
ANKZ | RADIO FREQUENCY RATING | 1.25 GIGAHERTZ MINIMUM AND 1.35 GIGAHERTZ MAXIMUM |
APGF | DESIGN TYPE | BIDIRECTIONAL |
APQB | UNIT TYPE | WAVEGUIDE |
BGPS | VOLTAGE STANDING WAVE RATIO AT REFERENCE FREQUENCY | 1.15V AT 1250 TO 1350 MHZ |
BGPX | POWER LOSS IN DECIBELS | 40.0 |
BGPY | TERMINAL FITTING NAME | RADIO FREQUENCY PLUG; FLANGE,WAVEGUIDE |
BGPZ | TERMINAL FITTING CONTROLLING AGENCY | JCENS |
BGQB | TERMINAL FITTING IDENTIFYING NUMBER | TYPE NO. UG-21B/U; TYPE NO. UG-418A/U |
BGQC | TERMINAL FITTING USAGE DESIGN | SECONDARY LINE AND MAIN LINE |
FEAT | SPECIAL FEATURES | CU-516/FPS-20; FUNCTION: DIRECTIONAL COUPLER; REFERENCE DATA: FIG 388-198, T.O. 31P6-2FPS20-4AD, SUPPLEMENTAL TECHNICAL MANUAL, ILLUSTRATED PARTS BREAKDOWN, RADAR SETS AN/FPS-67A, PG 2-16 |