5950-00-800-1242 Item Description: Transformer Power | 5950 | 008001242 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
722801-12 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.734 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.047 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 5.200 INCHES MINIMUM |
ACZB | FREQUENCY RATING | 57.0 HERTZ MINIMUM SINGLE COMPONENT AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 4.560 INCHES MINIMUM AND 4.590 INCHES MAXIMUM |
ADAT | BODY WIDTH | 3.870 INCHES MINIMUM AND 4.000 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 75.0 DEG CELSIUS |
AKPV | MOUNTING FACILITY QUANTITY | 8 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 30.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 8 STANDOFF, SOLDER LUG |
ADAU | BODY HEIGHT | 4.750 INCHES MINIMUM AND 4.940 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CMLP | THREAD QUANTITY PER INCH | 20 SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 110.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
722 00015 01 | 722-00 | 722 000 PLB | 722-0001 |
722 00015 00 | 722-0.812-SS-12 | 722-00005 | 722-00015-00 |
722 000 PLB | 722 000 PLB | 722-000-058 | 722 00014 00 |
722-00 | 722 00014 00 | 722 00015 01 | 722-000015-00 |