5950-00-433-1961 Item Description: Transformer Power | 5950 | 004331961 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
161695 | 6 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.735 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.735 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.765 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.765 INCHES MAXIMUM SINGLE MOUNTIN |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.735 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.735 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.765 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.765 INCHES MAXIMUM SINGLE MOUNTIN |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SIX PHASE SINGLE COMPONENTTHREE PHASE TO SIX PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYEDELTA-WYE |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.750 INCHES MAXIMUM3.750 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.750 INCHES MAXIMUM2.750 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 2.125 INCHES MAXIMUM2.125 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS155.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALEDHERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT1 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.83 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
CRMJ | WINDING POWER RATING | 89.67 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 416.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 49.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY416.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 11 TURRET |
161-0003-00 | 161-0-6 | 161-0-6 | 161-0001-00 |
161-0-6 | 161-0003 | 161-0005-E | 161-0001-00 |
161-00 | 161-0002 | 161-000477-00 | 161-000305-00 |
161-0005 | 161-0003-E | 161-0.75 | 161-0005 |