Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-356-3740 Item Description: Power Supply | 6130 | 013563740 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | B | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
109700 | 5 | 3 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 16.600 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 7.000 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | THREE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | -15.0 DC VOLTS NOMINAL 6TH OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 115.0 AC VOLTS MINIMUM 1ST OPERATING POWER RQMT AND 200.0 AC VOLTS MAXIMUM 1ST OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 15.0 DC VOLTS NOMINAL 4TH OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 6.3 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 6.6 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | -54.0/+71.0 DEG CELSIUS |
CWGH | OUTPUT CURRENT RATING | 1.1 DC AMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 109.0 DC MILLIAMPERES MINIMUM 3RD POWER OUTPUT AND 108.0 DC MILLIAMPERES MAXIMUM 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 2.0 DC MILLIAMPERES MINIMUM 2ND POWER OUTPUT AND 3.0 DC MILLIAMPERES MAXIMUM 2ND POWER OUTPUT |
CWGN | OUTPUT PHASE | THREE SINGLE POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 8 2ND POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 1.5 DC AMPERES NOMINAL 3RD OPERATING POWER RQMT |
CWHM | INPUT CURRENT RATING | 15.0 AC AMPERES MINIMUM 1ST OPERATING POWER RQMT AND 22.0 AC AMPERES MAXIMUM 1ST OPERATING POWER RQMT |
CWHM | INPUT CURRENT RATING | 5.0 DC AMPERES NOMINAL 5TH OPERATING POWER RQMT |
CWHQ | INPUT CONNECTION TYPE | CONNECTOR, RECEPTACLE 1ST ALTERNATE OPERATING POWER RQMT |
CWHQ | INPUT CONNECTION TYPE | CONNECTOR, RECEPTACLE 2ND ALTERNATE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 3 SINGLE OPERATING POWER RQMT |
CWGZ | RIPPLE VOLTAGE AT FULL LOAD | 10.0 VOLTS RMS 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 8 3RD POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 0.25 DC AMPERES NOMINAL 4TH OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 28.0 DC VOLTS NOMINAL 3RD OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 64.0 DC VOLTS NOMINAL 2ND OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 1.69 DC KILOVOLTS MINIMUM 3RD POWER OUTPUT AND 1.945 DC KILOVOLTS MAXIMUM 3RD POWER OUTPUT |
CWGZ | RIPPLE VOLTAGE AT FULL LOAD | 0.2 VOLTS RMS 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | CONNECTOR, PLUG SINGLE POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | CONNECTOR, RECEPTACLE 3RD ALTERNATE OPERATING POWER RQMT |
ADZC | ENVIRONMENTAL PROTECTION | SALT SPRAY PROOF |
AGAV | END ITEM IDENTIFICATION | ALQ184 |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | 50000.0 FEET |
APNX | INPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 5TH OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -3.9 DC KILOVOLTS MINIMUM 2ND POWER OUTPUT AND -3.896 DC KILOVOLTS MAXIMUM 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 8 1ST POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 0.1 DC AMPERES NOMINAL 6TH OPERATING POWER RQMT |
CWHM | INPUT CURRENT RATING | 1.2 DC AMPERES NOMINAL 2ND OPERATING POWER RQMT |
CWKG | VENTILATION DESIGN TYPE | CONVECTION |
FEAT | SPECIAL FEATURES | OUTPUT VOLTAGES AND CURRENT RATINGS ARE REQUIRED TO OPERATE ONE TWT. THIS POWER SUPPLY OPERATES 8 DIFF. TWT'S. OVERCURRENT PROTECTION,RELAY RESET WHEN POWER IS CYCLED ON AND OFF |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | SOURCE CONTROLED |
109-0005-00 | 109-0005-00 | 109 0007 00 | 109-000234 |
109-0007-010 | 109-000-298 | 109-00065-PW | 109-000-086 |
109 00008 0000 | 109 0007 01 | 109-0007-010 | 109-0005-00 |
109-000-234 | 109-00066-PW | 109-0002 | 109-000-086 |