MRC | Criteria | Characteristic |
---|---|---|
BGNL | MEASUREMENT RANGE | 0.5 TO 195.0 GALLONS PER MINUTE AND 0.3 TO 50.0 GALLONS PER MINUTE |
ASSB | MECHANICAL CONNECTION QUANTITY | 2 |
ASSC | MECHANICAL CONNECTION SIZE | 1.5 INCH PER AND10050 |
ASSD | MECHANICAL CONNECTION TYPE | MALE FLARED TUBE |
AFLW | ACTUATION METHOD | ANGULAR MASS MOMENTUM PRINCIPLE TURBINE ACTUATED AND MAGNET |
ASKX | ELECTRICAL CONNECTION QUANTITY | 1 |
AGAV | III END ITEM IDENTIFICATION | ENGINE TEST CELL A/M37-T20B FOR FUEL FLOW MEASUREMENTS;SECONDARY RANGES 175/75000 PPH AT A SPECIFIC GRAVITY OF0.7620 OR 125/21000 PPHAT A SPECIFIC GRAVITY OF 0.8220 |
ASKZ | ELECTRICAL CONNECTION IDENTIFYING NUMBER | PT02E-8-2P |
ABHP | OVERALL LENGTH | 13.500 INCHES NOMINAL |
AXGY | MOUNTING METHOD | FLANGE |
ADAV | OVERALL DIAMETER | 2.880 INCHES NOMINAL |
AARA | TERMINAL QUANTITY | 2 |
AARB | TERMINAL TYPE | CAPTIVE SCREW |
FEAT | SPECIAL FEATURES | MODE 1 OPERATION CALIBRATED FOR MIL-J-5624 AT A SPECIFIC GRAVITY OF 0.7620 AND MODE 2 MIL-H-5606 AT A SPECIFIC GRAVITY OF 0.8220;FREQUENCT OF 2.5/1450.0 HZ NOMINAL;PRESSURE RATED AT 3000.0 PSIG;19 PSID PRESSURE DROP AT MAX. FLOW;303 STAINLESS STEEL CONSTRUCTION WITH 2 ALUMINUM FLOW STRAIGHTENERS ONE UPSTREAM AND ONE DOWN;EXTENDED RANGE MAGNETIC PICKUP |
QAF-32-VWR-1SC | QAF(16 | QAF-24-VWR-1SC(ED | QAF24UWS08 |
QAF16-WRL-1SC TC | QAF24PUP01 | QAF-24-VWR-1SC | QAF24S518CHH7 |
QAF24S518CHH7 | QAF-32-VWR-1SC |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote