MRC | Criteria | Characteristic |
---|---|---|
CBBL | FEATURES PROVIDED | ELECTRICAL OVERLOAD PROTECTION AND LUMINOUS SCALE MARKING AND NONGLARE GLASS AND SELF-ILLUMINATION FACILITY AND ZERO ADJUSTER |
FEAT | SPECIAL FEATURES | NON-ILLUMINATED,TANK 6-260-1-F,FUEL OIL STORAGE |
AMKD | INDICATOR TYPE | DIAL W/POINTER |
SFTT | SURFACE TREATMENT | PAINT |
STYL | STYLE DESIGNATOR | RECTANGULAR SEMI-FLUSH MTG |
AQEC | MOVEMENT TYPE | MOVING COIL, PERMANENT MAGNET |
MATT | MATERIAL | STEEL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 SCREW AND 4 UNTHREADED HOLE |
AACT | CIRCUIT CURRENT FOR WHICH DESIGNED | DC |
BMNG | METER BODY HEIGHT BEHIND MOUNTING FLANGE | 1.225 INCHES MAXIMUM |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 1500.0 |
APMM | DIAL SCALE MARKING COLOR | BLACK SINGLE INDICATOR SINGLE RANGE |
NHCF | NUCLEAR HARDNESS CRITICAL FEATURE | NONHARDENED |
AMQY | INSTALLATION DESIGN | PANEL |
ABMK | OVERALL WIDTH | 6.700 INCHES MAXIMUM |
AQFY | BACKGROUND COLOR | WHITE SINGLE INDICATOR SINGLE RANGE |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.718 INCHES MINIMUM AND 0.732 INCHES MAXIMUM |
SPCL | SPECIAL TEST FEATURES | DRAWING IAW MIL-STD-100A; VIBRATION IAW MIL-STD-167; SHOCK IAW MIL-S-901;MARK IAW MIL-STD-130; SEAL IAW MIL-STD-108D |
CTQL | MOVEMENT SUSPENSION METHOD | JEWEL PIVOT BASE |
BLSB | SCALE SELECTION METHOD | TERMINAL |
ABTB | MOUNTING HOLE DIAMETER | 0.190 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1.530 INCHES MAXIMUM |
BHMW | MEASUREMENT RANGE | 0.0 TO 100.0 PERCENT SINGLE INDICATOR SINGLE RANGE |
ABWG | SCALE DIVISION QUANTITY | 50 SINGLE INDICATOR SINGLE RANGE |
AKYN | FURNISHED ITEMS AND QUANTITY | NUT 8; WASHER 16 |
ANRL | MOUNTING ARRANGEMENT STYLE | FOUR HOLE/STUD RECTANGULAR/SQUARE |
BHDC | SCALE GRADUATION TYPE | LINEAR SINGLE INDICATOR SINGLE RANGE |
CTWN | OPERATING VOLTAGE RATING IN VOLTS | 28.0 DC NOMINAL |
ANTG | SENSITIVITY RATING | 20.0 MILLIAMPERES |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
ZZZV | III FSC APPLICATION DATA | TEST SET,ELECTRONIC SYSTEMS,EXCEPT SPECIALLY DESIGNED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 6.043 INCHES MINIMUM AND 6.057 INCHES MAXIMUM |
APST | METER DEPTH BEHIND MOUNTING FLANGE | 5.770 INCHES MAXIMUM |
ABHP | OVERALL LENGTH | 7.730 INCHES MAXIMUM |
APSN | (NON-CORE DATA) PANEL FOR WHICH DESIGNED | MAGNETIC OR NONMAGNETIC |
ADZC | ENVIRONMENTAL PROTECTION | HUMIDITY RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT |
APSY | METER BODY WIDTH BEHIND MOUNTING FLANGE | 5.450 INCHES MAXIMUM |
BHSX | (NON-CORE DATA) CIRCUIT CONSTRUCTION TYPE | NONELECTRONIC |
ASSS | POINTER COLOR | RED SINGLE INDICATOR SINGLE RANGE |
SUPP | III SUPPLEMENTARY FEATURES | DAMPING FACTOR 10.0 MIN; RESPONSE TIME 2 SEC MAX; INSULATION RES 20 MEGOHMS MIN; EDGEWISE MTG; RUGGEDIZED |
APPN | ACCURACY IN PERCENT | -2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE |
AWZJ | POWER SOURCE | EXTERNAL |
CTTD | CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 THREADED STUD |
367-0005 | 367-0010-000 | 367-00 | 367-0014 |
367-0016-000 | 367-0005 | 367-0014-000 | 367-0013 |
367-00 | 367-0016-000 | 367-0005 | 367-0012-00 |
367-0011-00 | 367-00 | 367-0016 | 367-0014-000 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote