Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-01-075-0006 Item Description: Filter Band Pass | 5915 | 010750006 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
3702 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
BAND PASS | ABKW | OVERALL HEIGHT0 920 INCHES NOMINAL |
BAND PASS | ADAQ | BODY LENGTH2 380 INCHES MAXIMUM |
BAND PASS | ADAT | BODY WIDTH0 980 INCHES MAXIMUM |
BAND PASS | ADAU | BODY HEIGHT0 750 INCHES NOMINAL |
BAND PASS | AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2 000 INCHES NOMINAL |
BAND PASS | AECR | VIBRATION RESISTANCE RANGE IN HERTZ14 0 TO 200 0 |
BAND PASS | AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0 588 INCHES NOMINAL |
BAND PASS | AHAJ | REFERENCE FREQUENCY PER FUNCTION70 0 MEGAHERTZ BLANK |
BAND PASS | AHAU | INPUT IMPEDANCE PER FUNCTION WLOAD50 0 OHMS BLANK |
BAND PASS | AHAV | OUTPUT IMPEDANCE PER FUNCTION WSOURCE ACROSS INPUT50 0 OHMS BLANK |
BAND PASS | AHBZ | VOLTAGE STANDING WAVE RATIO PER FUNCTION2 1 BLANK |
BAND PASS | AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC |
BAND PASS | AKNA | INCLOSURE TYPEENCASED |
BAND PASS | AXHR | MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE |
BAND PASS | CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS13 0 BLANK |
BAND PASS | CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT 1ST FUNCTION |
BAND PASS | CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION67 00 MEGAHERTZ BLANK AND 69 90 MEGAHERTZ BLANK AND 70 10 MEGAHERTZ BLANK AND 73 00 MEGAHERTZ BLANK |
BAND PASS | CQJX | NOMINAL THREAD SIZE0 112 INCHES |
BAND PASS | CQRG | BODY MATERIALMETAL |
BAND PASS | CRBB | FREQUENCY BAND WIDTH PER FUNCTION69 90 MEGAHERTZ BLANK AND 70 10 MEGAHERTZ BLANK |
BAND PASS | CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS30 0 MINIMUM BLANK AND 1 0 MAXIMUM BLANK AND 1 0 MAXIMUM BLANK AND 30 0 MINIMUM BLANK |
BAND PASS | CRBN | VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION69 9 MEGAHERTZ BLANK AND 70 1 MEGAHERTZ BLANK |
BAND PASS | CRST | BODY SURFACE TREATMENTTIN |
BAND PASS | STYL | STYLE DESIGNATORRECTANGULAR TERMINALTERMINALS ON ONE SURFACE |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote