Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-200-1039 Item Description: Power Supply | 6130 | 012001039 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Htaa-16w-A | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 6.500 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1.620 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 4.000 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE 1ST OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 2ND OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 3RD OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 4TH OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 100.0 AC VOLTS NOMINAL 4TH OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 120.0 AC VOLTS NOMINAL 3RD OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 220.0 AC VOLTS NOMINAL 2ND OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 230.0 AC VOLTS MINIMUM 1ST OPERATING POWER RQMT AND 240.0 AC VOLTS MAXIMUM 1ST OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC POUNDS PER HOUR WET 2ND POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 15.0 DC POUNDS PER HOUR WET 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC POUNDS PER HOUR WET 3RD POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 3RD OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 3RD OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 4TH OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 4TH OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | +0.1/+50.0 DEG CELSIUS |
CWGH | OUTPUT CURRENT RATING | 2.0 DC AMPERES NOMINAL 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 400.0 DC MILLIAMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 400.0 DC MILLIAMPERES NOMINAL 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 3RD POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER STUD 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER STUD 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | SOLDER STUD 3RD POWER OUTPUT |
HTA 121 22 | HTA-1884 | HTA-250 | HTA-4-500 |
HTA-6-750 | HTA-125A | HTA 400-S SP2 | HTA 400-S SP2 |
HTA 400-S SP2 | HTA-182 115V 50 60 HZ | HTA 250 | HTA 4 500A |
HTA-200-S | HTA 121 22 | HTA-00 | HTA-125A |