NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5961-01-061-0288 Item Description: Transistor | 5961 | 010610288 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | A | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Bf247a | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 0.177 INCHES MINIMUM AND 0.188 INCHES MAXIMUM |
ABJT | TERMINAL LENGTH | 0.500 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 0.150 INCHES MINIMUM AND 0.165 INCHES MAXIMUM |
ALAS | INTERNAL CONFIGURATION | FIELD EFFECT |
ALAZ | JOINT ELECTRONIC DEVICE ENGINEERING COUNCIL/JEDEC/CASE OUTLINE DESIGNATION | R203C |
AXGY | MOUNTING METHOD | TERMINAL |
AYQS | TERMINAL CIRCLE DIAMETER | 0.100 INCHES NOMINAL |
CTMZ | III SEMICONDUCTOR MATERIAL | SILICON |
CTQN | VOLTAGE RATING IN VOLTS PER CHARACTERISTIC | 25.0 MAXIMUM BREAKDOWN VOLTAGE, DRAIN-TO-SOURCE, WITH ALL OTHER TERMINALS SHORT-CIRCUITED TO SOURCE AND 25.0 MAXIMUM BREAKDOWN VOLTAGE, GATE-TO-SOURCE, WITH ALL OTHER TERMINALS SHORT-CIRCUITED TO SOURCE |
CTRD | POWER RATING PER CHARACTERISTIC | 200.0 MILLIWATTS MAXIMUM TOTAL POWER DISSIPATION |
TTQY | TERMINAL TYPE AND QUANTITY | 3 UNINSULATED WIRE LEAD W/TERMINAL LUG |